TCT-2PAG11006MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: thread G ¼ B, Output signal: Pt100, 4-wire
TCT-2PASE1006MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: compression fitting G ½ B, stainless steel ferrule, Output signal: Pt100, 4-wire
TCT-2PBGE1006MZ, Temperature measuring range: -50 °C ... 250 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: thread G ½ B, Output signal: Pt100, 4-wire
TCT-2AAP41006MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: compression fitting ¼'' NPT, PTFE ferrule, Output signal: 4 mA ... 20 mA, 2-wire
TCT-2ABN21006MZ, Temperature measuring range: -50 °C ... 250 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: thread ½'' NPT, Output signal: 4 mA ... 20 mA, 2-wire
TCT-2PAGE3506MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 350 mm / 6 mm, Process connection: thread G ½ B, Output signal: Pt100, 4-wire
TCT-2PAG11506MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 150 mm / 6 mm, Process connection: thread G ¼ B, Output signal: Pt100, 4-wire
TCT-2PAS10253MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 25 mm / 3 mm, Process connection: compression fitting G ¼ B, CrNi stainless steel ferrule, Output signal: Pt100, 4-wire
LFR-XXUTAAMHAKX, Medium: Fluids, Process connection: Thread G ¾ PN20, DIN3852-A / 316LUp to 10 m (32.81 ft)thread with integrated horn antenna made from PEEK-40 °C ... 130 °CIP66 / IP68-1 bar ... 20 bar, (-100 kPa … 2,000 kPa / -14.5 psig … 290.1 psig)AluminumYesM20 x 1.5 / cable gland PA black (ø 5
LBR-XXBXDCMHAKX, Medium: bulk solids, Process connection: Mounting clamp, length: 300 mm / 316LUp to 120 m (393.7 ft), recommended measuring range in thread version with integrated horn antenna up to 20 m (65.62 ft)plastic horn antenna made from PP-40 °C ... 80 °CIP66 / IP68-1 bar ... 2 bar, (-100 k
TCT-2AATE1006MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: thermowell G ½ B, Output signal: 4 mA ... 20 mA, 2-wire
TCT-2ABTE1006MZ, Temperature measuring range: -50 °C ... 250 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: thermowell G ½ B, Output signal: 4 mA ... 20 mA, 2-wire
TCT-2AAT13506MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 350 mm / 6 mm, Process connection: thermowell G ¼ B, Output signal: 4 mA ... 20 mA, 2-wire
TCT-2PAT11006MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: thermowell G ¼ B, Output signal: Pt100, 4-wire
LBR-XXBXXCBHAKX, Medium: bulk solids, Process connection: without process connectionUp to 120 m (393.7 ft), recommended measuring range in thread version with integrated horn antenna up to 20 m (65.62 ft)plastic horn antenna made from PP-40 °C ... 80 °CIP66 / IP68-1 bar ... 2 bar, (-100 kPa … 200 kP
LBR-XXBXXCBHAXX, Medium: bulk solids, Process connection: without process connectionUp to 120 m (393.7 ft), recommended measuring range in thread version with integrated horn antenna up to 20 m (65.62 ft)plastic horn antenna made from PP-40 °C ... 80 °CIP66 / IP68-1 bar ... 2 bar, (-100 kPa … 200 kP
PBT-RB040AG2SS0AMA0Z, Pressure type: gauge pressure, Pressure unit: bar, Measuring range pressure: 0 bar ... 40 bar, Process connection: G ¼ female, Accuracy: <, Pressure port: Standard, Seal: without seal, Connection type: M12 round connector x 1, 4-pin, Enclosure rating: IP67, Non-linearity: <, Su
LFR-XXTTAABHKAX, Medium: Fluids, Process connection: Thread G ¾ PN20, DIN3852-A / 316LUp to 10 m (32.81 ft)thread with integrated horn antenna made from PEEK-40 °C ... 130 °CIP66 / IP67-1 bar ... 20 bar, (-100 kPa … 2,000 kPa / -14.5 psig … 290.1 psig)plasticYesM20 x 1.5 / plug connector M12 x 1 pin
LBR-XXCFBAMHAKX, Medium: bulk solids, Process connection: Flange DN 100 PN 16 form B, DIN 316 / 316LUp to 120 m (393.7 ft), recommended measuring range in thread version with integrated horn antenna up to 20 m (65.62 ft)metal jacketed lens antenna / PEEK / c/w air purge connection-40 °C ... 130 °CIP
LFR-ACFFHIMHAKX, Medium: Fluids, Process connection: flange DN 80 PN 40 form C, DIN 2501 / 316LUp to 30 m (98.43 ft)Flange with encapsulated antenna system-40 °C ... 130 °CIP66 / IP68In combination with process temperature -196 °C … +200 °C, -1 bar … 25 bar (-100 kPa … 2,500 kPa / -14.5 psig … 362.6
TCT-2AAT11006MZ, Temperature measuring range: -50 °C ... 150 °C, Insertion length/diameter of probe: 100 mm / 6 mm, Process connection: thermowell G ¼ B, Output signal: 4 mA ... 20 mA, 2-wire
UC40-11211B ,Product family: UC40, Technology: 65 mm, Maximum required distance: 350 mm, Housing material: plastic, Type of light:
UC40-11311B ,Product family: UC40, Technology: 200 mm, Maximum required distance: 1300 mm, Housing material: plastic, Type of light: